1、 DTRO classification: mainly divided into three types according to pressure level
1) 75bar DT membrane column
2) 120bar DT membrane column
3) 160bar DT membrane column
2、 Usage conditions:
1) The siltation index SDI is less than 20;
2) Free residual chlorine<0.1mg/L;
3) Suspended solids SS<1500mg/L;
4)COD<35000mg/L;
5) Ammonia nitrogen<2500mg/L;
6) 75 bar DT membrane column TDS < 30000mg/L;
120 bar DT membrane column TDS < 50000mg/L;
The TDS of the 160bar DT membrane column is less than 75000mg/L.
3、 Operating temperature and pressure:
a) Operating temperature: Operating temperature range of 5-45 ℃; When the temperature exceeds 45 ℃, a cooling device should be added, and when it is below 5 ℃, a preheating device should be installed.
b) Operating pressure:
The operating pressure of 75bar reverse osmosis should not exceed 7.5MPa;
The operating pressure of 120bar reverse osmosis should not exceed 12.0MPa;
The operating pressure of 160bar reverse osmosis should not exceed 16.0MPa.
4、 Recovery rate:
Single membrane module recovery rate: 20-50%.
Integrated equipment raw water recovery rate:
——The conductivity of raw water is less than or equal to 1000 μ s/cm, and the recovery rate of raw water is greater than or equal to 90%;
——The conductivity of raw water is less than or equal to 5000 μ s/cm, and the recovery rate of raw water is greater than or equal to 85%;
——The conductivity of raw water is less than or equal to 15000 μ s/cm, and the recovery rate of raw water is greater than or equal to 80%;

——The conductivity of raw water is less than or equal to 20000 μ s/cm, and the recovery rate of raw water is greater than or equal to 75%;
——The conductivity of raw water is less than or equal to 30000 μ s/cm, and the recovery rate of raw water is greater than or equal to 70%.
When the salt content of raw water is higher, the recovery rate of raw water should be designed according to specific requirements.
5、 Service life: 5-10 years.
6、 Single membrane module parameters:
Membrane area: 9.4m2
Total length of membrane module: 1400mm
7、 Application Fields
Zero discharge pretreatment of leachate, seawater desalination, high salt wastewater, chemical wastewater, emergency mobile water supply and other fields.

8、 Product Technical Parameters
DT membrane column specification parameters
Project unit: Low pressure membrane module, medium pressure membrane module, high pressure membrane module
DTRO-75 DTRO-120 DTRO-160
Inlet flow rate L/h 250-1600 400-1500
Inlet flow rate during operation L/h 500-1200
Maximum temperature ℃ 45
Maximum operating pressure bar 75 120 160
Operating pressure during operation bar 30-75 90-120 90-160
Test pressure bar 100 130 200
Total length mm 1400 1400 1400
Outer diameter of pressure vessel mm 214 233 233
Number of single membrane element guide plates: 210, 210, 210
Single membrane element, number of membrane sheets 209 209
Total membrane area of a single membrane element m2 9.4 9.4 9.4
Net weight of a single membrane element kg 66 82 88
Total weight of a single membrane element
(During operation) kg 74 96 96
DT membrane column material
Pressure vessel FRP
Center rod SS
Water distribution end plate SS/PP
Guide plate ABS
Diaphragm PA
Lip seal ring EPDM
O-ring fluororubber
Product performance of DT membrane column
Remarks on the removal rate of bullet units
Chemical oxygen demand CODcr% ≥ 99.5
Biochemical oxygen demand BOD5% ≥ 99.5
Ammonia nitrogen NH4-N% ≥ 90.0
Suspended solids SS% ≥ 99.9
Organic halide AOX% ≥ 99.6
Heavy metal% ≥ 99.0
Conductivity CT (20 ℃)% ≥ 98.5
Total solid content TDS% ≥ 98.5
Note: The above removal rate is based on the inlet water temperature of 20 ℃. For every 5 ℃ increase in temperature, the removal rate decreases by 0.5% to 1.0%, and vice versa, it increases by 0.5% to 1.0%